How to Fit an Outside Tap: Parts, Regulations and Step by Step

Updated 6 min readBy the London Plumbing Supplies counter team

The short answer

Tee into the mains cold pipe after the stop tap — usually under the kitchen sink — and run 15mm pipe through the wall to a wallplate elbow and a 1/2" hose union bib tap. The water regulations require backflow protection: a double check valve, fitted on the pipe indoors or built into the tap. Add a lever isolating valve inside so you can turn the tap off and drain it before winter, and insulate any pipe outside.

What you need for an outside tap

An outside tap kit is a bundle of the parts below. We sell them separately, so you can choose the tap, the valves and the length of pipe through the wall:

Parts for a typical outside tap
PartWhyOurs
15mm teeTakes a branch off the cold mainCompression tees
15mm lever isolating valveTurns the outside tap off from indoors, for repairs and winterIsolating valves
Double check valveThe backflow protection the regulations require, unless it's built into the tap15mm double check valve, £4.37
Through-wall pipe and wallplateCarries the pipe through the wall to a fixed 1/2" thread for the tapWallplate adaptor with 350mm pipe or 600mm pipe; or a compression wallplate elbow on your own copper
1/2" hose union bib tapThe tap, with a threaded outlet for a hose connectorBrass bib tap, £6.68, or with a built-in double check valve, £8.34
Sealing and laggingSeals the thread and the hole; protects against frostPTFE tape, silicone sealant, pipe insulation

Want to stop passers-by using it? Our lockshield bib tap only turns with its loose key.

Outside taps

Do outside taps need a double check valve?

Yes. A hose left in a puddle, a paddling pool or a bucket of garden chemicals can be drawn back into the mains if the pressure drops — that's backflow. The Water Supply (Water Fittings) Regulations 1999 require protection against it, and for a hose union tap at a house that means a double check valve, either built into the tap or fitted on the pipe that feeds it.

  • Double check valve indoors: fit it after the isolating valve, with its arrow pointing towards the tap, somewhere warm and reachable.
  • Bib tap with a built-in double check valve: one part does both jobs — handy when you can't get at the pipe indoors.
  • Commercial, agricultural and higher-risk uses — livestock troughs, irrigation, mixing chemicals — need a higher level of protection, such as an air gap. That's a job for an approved plumber.

An ordinary hand-operated outside tap doesn't need to be notified to your water company, but an automatic garden watering system does, before it's installed — as does any new pipe laid less than 750mm or more than 1,350mm below ground. The regulations apply to DIY work too; a WaterSafe-approved plumber can certify that their work complies.

Double check valves

Where to put it and where to tee in

  • Tee into the mains cold, after the internal stop tap, so the stop tap controls the outside tap too. Under the kitchen sink is the usual spot. Don't take it from a loft tank or a hot pipe.
  • Keep the indoor run short, and go through the wall close to where you tee in.
  • Choose the outside spot: at a comfortable height, over a path or gully rather than against a flower bed if you can, and clear of doors and windows that open outwards.
  • Check for hidden services — cables, gas pipes and drains — on both sides of the wall before drilling.
  • Go through above the damp-proof course, which is normally at least 150mm above ground level.

How to fit an outside tap, step by step

  1. Mark the hole inside and out. Drill through with a long SDS masonry bit a little bigger than the pipe — bigger again if you're sleeving it — falling very slightly towards the outside.
  2. Turn off the water at the stop tap and drain the cold from the kitchen tap.
  3. Cut in the 15mm tee, then fit the lever isolating valve, then the double check valve with its arrow pointing towards the tap.
  4. Feed the through-wall pipe out and screw the wallplate to the wall with plugs, so the tap won't twist when you use it.
  5. Join the indoor run to the through-wall pipe and clip it — see clip spacing for copper.
  6. Wrap PTFE tape clockwise round the tap's thread, screw it into the wallplate and finish with the spout pointing straight down. If you go past, take it out and re-tape rather than unwinding it.
  7. Seal round the pipe where it goes through the wall, inside and out.
  8. Turn the water on, open the isolating valve, run the tap to clear air and debris, and check every joint.

Prefer to work without a blowtorch? Compression or push-fit tees and valves do the whole job — see compression vs push-fit vs solder.

Going through the wall

  • Measure the wall at a door or window reveal, and choose a through-wall pipe long enough to reach your connection inside: the wallplate adaptors come with 350mm or 600mm of copper.
  • Fall to the outside. A slight slope outwards stops water tracking back into the wall — important across a cavity.
  • Sleeve it. A short length of larger pipe through the hole protects the copper and lets it move; seal both ends.
  • Timber-framed and clad walls have membranes that must stay sealed. If you're not sure what's behind the outer skin, ask a builder or plumber first.

Protecting an outside tap from frost

An outside tap is usually the first thing in the house to freeze. Each autumn:

  1. Close the isolating valve inside.
  2. Open the outside tap so the pipe between the double check valve and the tap drains, and leave it open over winter.
  3. Insulate any exposed pipe, and fit an insulated cover over the tap.

Our guide to stopping pipes freezing covers lagging and what to do if a pipe freezes.

Self-seal pipe insulation

Upgrading an old outside tap

Many older outside taps have no backflow protection, and no valve indoors to turn them off. If you're replacing one, put both right: fit a lever isolating valve and a double check valve on the pipe inside, or — if you can't get at the pipe — a bib tap with the double check valve built in.

Most homes use a 1/2" bib tap on 15mm pipe; 3/4" bib taps give more flow for larger hoses. A dripping outside tap usually just needs a new washer — see how to fix a dripping tap. For hose fittings, see our hose connectors.

Questions

Do I need a double check valve on an outside tap?
Yes. Under the Water Supply (Water Fittings) Regulations 1999, a hose union tap at a house needs backflow protection: a double check valve, built into the tap or fitted on the pipe that feeds it.
Do I need permission to fit an outside tap?
Not for an ordinary hand-operated tap, but it must meet the water regulations. An automatic garden watering system must be notified to your water company before it's installed.
Where should the isolating valve for an outside tap go?
Indoors, on the new branch just after the tee, where you can reach it — under the kitchen sink is typical. The double check valve goes after it.
Can I use a self-cutting tee for an outside tap?
Many kits include one, and it saves cutting the pipe, but it restricts the flow and relies on a clamped seal. A compression tee is the more reliable joint.
What size is an outside tap?
Most homes use a 1/2" hose union bib tap on 15mm pipe. 3/4" bib taps give more flow for bigger hoses.
Should I leave my outside tap open in winter?
Yes — once you've closed the isolating valve indoors, leave the outside tap open so the pipe stays empty.